FERC paved the way for smart grid solutions. States must take the next step.

Rich Glick and Neil Chatterjee | Source: Utility DIVE | Posted 08/19/2025

Keyword Tags:

Grid-enhancing technologies and high-performance conductors offer a means for grid planners to quickly squeeze more out of existing transmission lines and rights-of-way.


AI generated summary

The article discusses the urgent need for the United States to enhance its electric grid infrastructure to meet the anticipated increase in electricity demand, projected to rise by 15.8% by 2029. With the growth of data centers and manufacturing plants, the demand for power could require an additional 65 to 90 GW. While building new power plants is essential, the article emphasizes the importance of expanding transmission capacity, which is currently lagging behind demand. Grid-enhancing technologies (GETs) and high-performance conductors (HPCs) offer immediate solutions to optimize existing transmission lines, improve efficiency, and reduce energy losses.

Despite the benefits of GETs and HPCs, misaligned economic incentives often hinder their integration into utility planning. The Federal Energy Regulatory Commission (FERC) has made strides in promoting these technologies, but the article stresses that states must now take action. Recent resolutions and legislation from state regulators indicate a growing recognition of the need for advanced transmission technologies. By leveraging these innovations, states can support economic growth through reliable and cost-effective power solutions, ensuring that the electric grid can meet future demands effectively.



Link to Original Article

Please find the link to the full article below. (Please note that content provider might require a paid subscription)


Source Link: https://www.utilitydive.com/news/smart-grid-gets-grid-enhancing-hpc-states/757687/

Create a free trial account: Sign Up

Grid monitor is free to try. No credit card required


Already have an account? Login

Most Active PUCT Filings

APPLICATION OF EL PASO ELECTRIC COMPANY FOR AUTHORITY TO CHANGE RATES - (140 filings)

CY 2025 RETAIL PERFORMANCE MEASURE REPORTS PURSUANT TO 16 TAC 25.88 - (137 filings)

APPLICATION OF ONCOR ELECTRIC DELIVERY COMPANY LLC FOR AUTHORITY TO CHANGE RATES - (122 filings)

CY 2024 RETAIL ELECTRIC PROVIDER (REP) ANNUAL REPORTS AND CY 2025 REP SEMI-ANNUAL REPORTS PURSUANT TO 16 TAC 25.107(I) - (112 filings)

BROKER REGISTRATIONS - (86 filings)

APPLICATION OF ENTERGY TEXAS, INC. TO AMEND ITS CERTIFICATE OF CONVENIENCE AND NECESSITY FOR THE CYPRESS-TO-LEGEND 500-KV TRANSMISSION LINE IN HARDIN AND JEFFERSON COUNTIES - (80 filings)

APPLICATION OF ONCOR ELECTRIC DELIVERY COMPANY LLC TO AMEND ITS CERTIFICATE OF CONVENIENCE AND NECESSITY FOR THE BORDER SWITCH-TO-CLEARFORK SWITCH 345-KV TRANSMISSION LINE IN ANDREWS, ECTOR, LOVING, AND WINKLER COUNTIES - (38 filings)