Fire Suppression in Battery Energy Storage Systems: Why Immersion Cooling Offers a Safer Future
Matthew Ward | Source: Power | Posted 05/06/2025
Battery Energy Storage Systems (BESS) are revolutionizing our power grids, dramatically enhancing resilience, and facilitating greater integration of renewable energy sources like solar and wind.
AI generated summary
Battery Energy Storage Systems (BESS) are transforming power grids by enhancing resilience and integrating renewable energy sources, but they also pose significant fire safety risks, particularly due to thermal runaway incidents in lithium-ion batteries. High-profile fires at facilities like Moss Landing and McMicken highlight the inadequacies of traditional fire suppression methods, necessitating a shift towards innovative solutions. Immersion cooling technology has emerged as a promising approach, effectively preventing ignition and controlling thermal events from the outset.
Immersion cooling involves submerging battery cells in a non-conductive dielectric fluid, which not only manages heat efficiently but also provides passive fire suppression by displacing oxygen and isolating failing cells. This method reduces the risk of thermal runaway and enhances the overall safety and sustainability of BESS installations. As traditional suppression methods struggle to address the unique challenges posed by lithium-ion fires, adopting immersion cooling systems like EticaAG's LiquidShield can significantly improve fire safety and operational reliability in energy storage systems.
Link to Original Article
Please find the link to the full article below. (Please note that content provider might require a paid subscription)05/06 - 9:30 AM
LEGE - House State Affairs05/07 - 8:00 AM
LEGE - House Natural Resources05/07 - 8:00 AM
LEGE - Senate Natural Resources05/07 - 9:00 AM
05/06/2025
The coolest new energy storage technologies05/06/2025
House Bill 3556 Endangers Valuable Energy Projects05/06/2025
Fire Suppression in Battery Energy Storage Systems: Why Immersion Cooling Offers a Safer Future05/06/2025
Microsoft inks agreement with Nexamp for 300 MW of new community solar05/06/2025
US solar, battery manufacturing to expand through 2027 despite uncertainty: Anza RenewablesAPPLICATION OF ENTERGY TEXAS, INC. TO AMEND ITS CERTIFICATE OF CONVENIENCE AND NECESSITY FOR THE SETEX AREA RELIABILITY PROJECT IN JASPER, MONTGOMERY, NEWTON, POLK, SAN JACINTO, TRINITY, TYLER, AND WALKER COUNTIES - (308 filings)
CY 2024 ANNUAL POWER LINE INSPECTION & SAFETY REPORT IN PURSUANT TO 16 TAC § 25.97(F) - (85 filings)
APPLICATION OF EL PASO ELECTRIC COMPANY FOR AUTHORITY TO CHANGE RATES - (80 filings)
APPLICATION OF CENTERPOINT ENERGY HOUSTON ELECTRIC, LLC FOR APPROVAL OF ITS 2026-2028 TRANSMISSION AND DISTRIBUTION SYSTEM RESILIENCY PLAN - (80 filings)
PROJECT TO SUBMIT EMERGENCY OPERATIONS PLANS AND RELATED DOCUMENTS UNDER 16 TAC § 25.53 - (71 filings)
BROKER REGISTRATIONS - (70 filings)
COMPLAINT OF VALERO REFINING-TEXAS, LP AGAINST TEXAS-NEW MEXICO POWER COMPANY - (58 filings)