ERCOT Congestion Management Working Group Meeting Notes - 10/18/21
Grid Monitor - staff writer | Source: Grid Monitor | Posted 10/18/2021
Agenda
1. |
Antitrust Admonition |
2. |
Agenda Review |
3. |
RUC for Congestion on 9/21/21 · ERCOT presentation posted and given (RUC for Congestion 20210921). · There was a lengthy discussion about where the constraints were versus the location of units that were RUC’d. · ERCOT was also asked why they RUC’d units on this day: to address binding constraints or for voltage support. (i.e., are they RUC’ing for reliability or economics). They answered that there were violations that they were resolving. They were asked about the relationship between units around Houston and issue in west Texas, and whether resource-specific information can be revealed. ERCOT could not give this specific information, but there was an unresolved contingency in the Houston area due to lack of generation and reactive support, and restricted flow in the west Texas GTC due to outages. Houston generation was committed because the voltage issues were in the Houston area. · They were asked about the relationship between SCED and shadow prices. ERCOT didn’t have the specific information in front of them, but indicated that the RUC helped relieve these constraints. ECOT may do an analysis on this. · ERCOT will provide additional information next month based on this discussion.
|
4. |
Improving the CRR Auction Models · A presentation was given on this last month, and the presenter followed-up on the discussion. The main issue is that short -term derates were being included in the long-term auctions. · Three options were proposed to address concerns that were raised and an SCR would likely be necessary: 1. Including an estimated end date for NOMCR submission. TSP’s had some concerns about operational impact of this idea and the question was asked about what would happen if the derate lasted longer than expected and the TSP forgot to update the NOMCR. However, ERCOT initially thought that this option might be the most accurate because it would be specific to each outage. This could result in an incorrect line rating, but the operational impact would be mitigated if they system is set up not to trigger anything based on the end date provided. This issue could be addressed in the SCR. 2. Requiring TSP’s to submit a corresponding NOMCR to bring the derated line back to its original/updated rating. It was pointed out that this could result in an incorrect line rating if the actual work completed differs from what was input. 3. Include a flag that designates a line outage as temporary. TSP’s though it was interesting because they might be able to use this flag for other things. ERCOT thought this might result in a bigger window and result in incorrect inclusion of outages. · This discussion will continue next month and is also being discussed at NDSWG.
|
5. |
RENA Update (Questions Only) · ERCOT presentation posted (Review of July RENA CMWG).
|
6. |
Other Business · A question was asked about whether PST’s were being optimized in the CMWG auction model. ERCOT answered that these still are being optimized and will continue to be.
|
7. |
Adjourn |
04/26 - 8:30 AM
ERCOT - DSWG Meeting - Webex Only04/26 - 9:30 AM
ERCOT - ADER Task Force: Quarterly Meeting04/26 - 2:00 PM
ERCOT - SSWG Meeting04/29 - 9:30 AM
04/26/2024
US solar panel makers seek import tariffs to protect new domestic factories04/26/2024
Texas offers grants for power companies to expand04/26/2024
Biden spending $16B on Texas clean energy, will Austin build a reliable electric grid?04/26/2024
Texas gas producers face uncertain future under new EPA power rules04/26/2024
Energy storage market grew faster than ever in 2023, BESS was most invested-in energy tech, according to BNEF, IEAAPPLICATION OF CENTERPOINT ENERGY HOUSTON ELECTRIC, LLC TO AMEND ITS CERTIFICATE OF CONVENIENCE AND NECESSITY FOR A PROPOSED 138-KV TRANSMISSION LINE IN HARRIS AND MONTGOMERY COUNTIES - (143 filings)
APPLICATION OF AEP TEXAS INC. FOR AUTHORITY TO CHANGE RATES - (106 filings)
CY 2023 ANNUAL POWER LINE INSPECTION & SAFETY REPORT IN PURSUANT TO 16 TAC ยง 25.97(F) - (99 filings)
APPLICATION OF CENTERPOINT ENERGY HOUSTON ELECTRIC, LLC FOR AUTHORITY TO CHANGE RATES - (70 filings)
APPLICATION OF LCRA TRANSMISSION SERVICES CORPORATION FOR AUTHORITY TO CHANGE RATES - (59 filings)
BROKER REGISTRATIONS - (48 filings)
APPLICATION OF ONCOR ELECTRIC DELIVERY COMPANY LLC TO AMEND ITS DISTRIBUTION COST RECOVERY FACTOR AND UPDATE MOBILE GENERATION RIDERS - (39 filings)