Meeting Summary - 04/22/2025 RTCBTF Meeting

Grid Monitor AI | Posted 04/23/2025

Keyword Tags:

 

▶️1 - Anti-trust Admonition

▶️2 - RTCBTF Update

2_RTCBTF_Update_04222025.pdf

▶️2.1 - Update on NPRRs at Board

  • Reviewed the old issues list with positive progress shown; more items marked as completed.
  • Acknowledgment of TAC and board approval for NPRR1268, NPRR1269, and NPRR1270, scheduled for commission consideration on May 15.
  • Development of new aggregated ORDC curve, AS demand curves, and proxy offer logic is underway.
  • Discussion on the state of charge duration parameter is planned; another revision anticipated for the June Board meeting.
  • Emphasis on ongoing market trials and planning for load frequency control (LFC) tests through April, May, and June.
  • Preparations for the go-live transition plan expected, including potential parallel data submissions and dual model day-ahead runs.
  • Consideration of protocol exemptions for LFC testing and go-live transition.
  • Acknowledgment of approved NPRRs and upcoming focus on state of charge discussions.
  • Clarification NPRR for June 18 regarding settlement corrections to align with protocols.
  • Highlighting NFRC telemetry updates requiring maintenance of specific data attributes for NERC evaluations.
  • Offer bid structure cleanup in progress, addressing monotonically non-increasing language on bids.

▶️2.2 - Update on Scorecard

  • TAC meetings scheduled for May leading to a June board meeting, and for August leading to a September board meeting.
  • No other board meetings until the meeting in December, after going live.
  • No changes in the market trial sequence; handbooks provide guidance on market submissions, telemetry startup, and open loop scheduling.
  • Final reviews for open loop scheduling and QSE telemetry test, initial reviews for closed loop LFC test and day ahead.
  • New market trials and tech support folders available on the RTCBTF homepage.
  • Plan to add four more training videos before the next meeting.

▶️2.3 - Update on Weekly WebEx Market Trials (Market Notice sent 4/16)

  • Market trials will use a central location for key documents like handbooks and technical details, located on the RTCBTF homepage.
  • The RTCB@ercot.com mailbox is operational and is managed to ensure quick responses.
  • Training videos are planned to aid in the market trials process.
  • ERCOT engaged with the demand side working group for load resource participation training.
  • A special session with the demand side working group was conducted with a focus on their participation in market trials.

▶️2.4 - Operator Training Seminar Update

  • Operator training seminars have been conducted every Wednesday for the past month.
  • The seminars cover RTC basics and operations, with a focus on telemetry changes.
  • 600-800 operators have participated in the training at the T4 control center in Taylor.
  • Training sessions will conclude next Wednesday, with a focus on technical details related to RTC.
  • Preparation for formal market trials starting May 5th was discussed.
  • A market notice was sent on March 13 to ensure market participants were aware of upcoming market trial activities.
  • A 100% response rate was achieved for confirming readiness for the trials.
  • A second notice was sent regarding mandatory real-time co-optimization and battery market trials for all QSEs with resources starting May 5.
  • Market trial schedules and expectations from May through October were outlined for participants.

▶️2.5 - Model Schedule Posted

  • Model load information is being posted to the RTCBTF homepage.
  • Network model, EMS system, and market management system topology were discussed.
  • New resources and their display on the model load schedule were mentioned.
  • Highlighted the posting of the model schedule as a housekeeping item.

▶️3 - State of Charge / AS Duration Discussion

3_RTCTF_Duration_Requirements_Topic_Update_v6.pdf

  • A presentation was given on the analysis updates regarding Non-Spin resources, specifically online Non-Spin resources, and how they were being deployed.
  • It was noted that the analysis did not change the initial recommendation to recommend that Non-Spin duration lasts at least 4 hours.
  • Online Non-Spin capacity must be offered at a minimum of $75 per megawatt hour as per the protocols, with this capacity being available to SCED for deployment as needed.
  • An estimation was conducted to evaluate the deployment of online Non-Spin resources by SCED.
  • Historical data from 06/01/2018 to 03/27/2025 was analyzed, showing that 81% of events had a duration of four hours or more.
  • Questions were raised regarding the impact of different price floors on the event patterns and on the reliability determination.
  • A discussion was held on a specific date's analysis where forecast errors led to extended deployment of Non-Spin capacity.
  • Nitika Mago presented that the deployment patterns are driven by weather events and forced outages, which are difficult to forecast accurately.
  • Clarifications were made regarding the adjustments to battery state of charge calculations and their implications for the reliability need analyses.
  • It was concluded that the information shared did not change the existing recommendation but highlighted the usage of Non-Spin capacity during system demands.

▶️3.1 - Draft NPRR

3_XXXNOGRR-01-Related-to-NPRRXXX-Ancillary-Service-Duration-during-Real-Time-Co-Optimization-04XX25.pdf

3_XXXNPRR-01-Ancillary-Service-Duration-Under-Real-Time-Co-optimization-04DD25.pdf

  • The draft NPRR includes additional sections for clarity on qualification and monitoring criteria.
  • Key changes introduced include adjusting durations in various sections with acronyms established for consistency.
  • In reliability unit commitment, a new paragraph includes a 60-minute duration for energy and ancillary services, excluding RRS provided using fast frequency response with a 15-minute duration.
  • Changes include replacing a 15-minute duration with 30 minutes in regulation and responsive reserve.
  • Adjustments also seen in monitoring criteria, replacing 15 minutes with 30, and ECRS criteria changed from two hours to one hour.
  • Discussion on the impact of Non-Spin resource qualification and ECRS.
  • Nitika Mago addressed the revisions focusing on regulation updates and ERCOT’s intention to file the NPRR.
  • Stakeholder comments emphasized the importance of ensuring market stability and considerations for evolving reserve durability.
  • Concerns raised regarding state of charge (SOC) limits and how language applies to breakdown scenarios.
  • Further inquiries included how the NPRR aligns with security constraints and socioeconomic dispatch parameters, ensuring it doesn’t violate max/min SOC limits.
  • Clarification provided that adjustments are needed when transitioning from a combo model to a single model concerning ESR registration.
  • Queries about the impact of the NPRR changes on day-ahead market ancillary services.
  • Stakeholders invited to provide further comments or proposals before the next session, with potential for additional sessions based on feedback.

▶️4 - Market Readiness

  • Discussion focused on the handbooks, with emphasis on transparency regarding recent modifications.
  • Acknowledgment of feedback loop necessity in case of issues with handbook updates.
  • Nathan Smith assisted in correcting handbook information regarding AS capability fields.
  • The field is not new but rather an adjustment from a single value to a megawatt value.
  • Clarification on telemetry checkout language to reflect that not all checkouts are complete but telemetry verification is recognized as success.
  • The language around telemetry verification has been softened to align with current progress and understanding.

▶️4.1 - Review Handbook #3- Open Loop SCED (Round 3-Final)

4_RTCB_Market_Trials_Handbook_3_OpenLoop_RTC_SCED_04182025_FINAL.pdf

  • Specific sections of the handbook are marked in green to indicate completion by ERCOT; this helps to show what the QSE needs to accomplish.
  • Section three of the handbook is crucial and has been discussed in past meetings.
  • ERCOT will run RTC SCED in the market trials environment using market submissions and telemetry, with published prices and dispatch information.
  • Introduction of 'non-monitored operating days' where QSEs submit real-time offers with 80%-120% cost representation. Participation is not enforced but expected to improve market results.
  • NPRR1058 allows all resources to update offers during the operating hour, with a mandatory reason in the text field for changes.
  • SCED-generated capacity prices will be published by interval on ERCOT.com; reports must be downloaded as no dashboards or specific displays will be provided.
  • SCED operations will occur on business days, specifically Tuesdays and Thursdays from 9 to 5, which provides a regular schedule for participants.
  • The handbook is being finalized and flagged as complete, but changes can be made if necessary.
  • There was a question about schema changes for recent code requirements; it was clarified that the reason field is already part of submissions and will be validated during the operating period.
  • The same update logic for energy offer changes will apply to AS offer submissions, pending confirmation.

▶️4.2 - Review Handbook #4- QSE Telemetry Tests (Round 3-Final) Abhi Masanna Gari

4_RTCB_Market_Trials_Handbook_4_QSE-Telemetry-Tests_04182025_FINAL.pdf

  • Presented the proposed final version of the QSE telemetry tests.
  • Tweaked the handbook for better clarity and specificity.
  • Discussed the parallel test window running alongside the open loop schedule.
  • Emphasized the need for accurate telemetry to support the market solution.
  • Outlined the coordination of individual QSE tests on selected resources for point-to-point telemetry checkout.
  • Clarified that QSE tests don't involve the whole fleet, only selected resources.
  • Set test times to Tuesday and Thursday, nine to five.
  • Open to observed or self tests, with ERCOT in knowledge of the tests.
  • Clarified that CLRs will not require additional tests.
  • Mentioned forms, sheets, and expectations will be provided as the process progresses.
  • Plans to put the finalized document on the website.
  • Discussion involving Nathan Smith and Dave Maggio on energy offer curves and the ability to update ancillary service offers.
  • Clarified the distinction between energy offers under NPRR1058 and RTCTF discussions.

▶️4.3 - Review Handbook #5- Close-Loop LFC Tests (Round 1-Initial)

4_RTCB_Market_Trials_Handbook_5_ClosedLoop_LFC_DRAFT_04182025.pdf

  • Introduction of a new frequency control test from September to October, described as challenging.
  • Proposal of a two-hour test with QSE participation, ensuring reliable RTC SCED dispatch and frequency control without significant operational disruption.
  • ERCOT to provide a minimum of ten business days advanced notice before test dates, with tests conducted to prevent frequency issues.
  • Details on managing transition risk through parallel production systems and binding RTC SCED during tests.
  • Minimizing the risk of significant redispatch through guardrails requiring QSEs to enter identical energy offer curves for both current and RTC systems.
  • Specific instructions for AS responsibilities: $0 offers for resources carrying responsibilities and $2,000/megawatt for others.
  • Consideration of current duration requirements over RTC during LFC tests for ESRs with response AS responsibility.
  • Telecom assumptions for QSEs and possible test run LFC to ensure QSE offers and telemetry are functioning prior to main tests.
  • Detailed test execution phases involving gradual QSE transition to RTC control, minimizing frequency swings during the test’s two-hour window.
  • Clarification on AS trades or changes within the test window, ensuring QSE can update offers as needed.
  • Financial settlements during tests based on current system prices, exempting base point deviation charges to prevent penalties.
  • Dispute conditions limited to financial harm instances, with criteria based on protocol 6.6.9(4)
  • Discussion on potential repeat of the test twice if needed, with adjustments based on findings.

Key Participants

  • ERCOT representatives introducing and explaining the test process.
  • Q&A from attendees like Ned Bonskowski, Dave Maggio, and Chris Espinosa providing additional inquiries on operational details.
  • Questions addressing specific scenarios like AS responsibility shifts and telemetry requirements.

Next Steps

  • Take feedback back to respective teams and provide additional questions or concerns in the next round of discussions.
  • Refine clarifications on AS offer protocols and test logistics prior to next meeting.

▶️4.4 - Review Handbook #6- Day-Ahead Market Tests (Round 1-Initial)

4_RTCB_Market_Trials_Handbook_6_DayAheadMarket_DRAFT_04182025.pdf

  • Voluntary Day-Ahead Market
    • The day-ahead market is voluntary post-RTC go live.
    • Day-ahead market participation is encouraged but not mandatory in readiness metrics.
    • Ancillary services (AS) are expected to have a liquid market.
    • The market will open to all QSEs, not just the existing participants.
  • Market Participation
    • QSEs can test market submissions like energy bids and AS offers.
    • Specific transactions for energy storage can be submitted.
    • Resource-specific AS offers can be submitted.
  • ESRs and Market Testing
    • ESR (energy storage resources) names updated in the system.
    • ESRs are available in RTCB environment for testing.
    • Questions about inclusion and updating of ESR lists were discussed.
  • Market Trials and Advisory Obligations
    • Day-ahead market tests are advisory with no binding commitments.
    • Details about AS scheduling limits were clarified.
    • Adjustment period is separate and not linked to closed loop tests.
  • Upcoming Sandbox and Reports
    • Publicly available sandbox data to be discussed at a later point.
    • Reports update planned for upcoming meetings.
  • Closing Remarks and Follow-ups
    • Finalization of handbook items discussed.
    • Feedback on day-ahead market and closed loop testing to be sought in next meeting.

▶️5 - Review 3 New Training Modules

▶️5.1 - Day-Ahead Market Training

5_RTCB_DAM_Training_v04182025.pdf

  • Overview of day-ahead market changes in the RTC+B era compared to current operations.
  • Reminder of the day-ahead market timeline which remains unchanged, including AS obligations and incentive service demand curves.
  • Introduction of three different AS submissions: AS only (new), resource specific, and self-arrangement.
  • No minimum obligation for AS submissions; advisory and final AS obligations calculated using LSE's load ratio share.
  • Shift in AS demand curve structure, moving away from an AS penalty cost structure to using AS demand curves in RTC.
  • AS insufficiency process modifications where insufficiency may lead to market reopening for additional offers.
  • Introduction of AS only offers in RTC without resource ties, limited to specific AS types, and subject to a new credit exposure calculation.
  • Resource specific offers to continue with some modifications, and a new optimization focus on AS demand curves.
  • Self-arrangement can't exceed advisory obligation in RTC, and negative self-arrangements treated as price takers.
  • Energy Storage Resources (ESRs) to have a single model incorporating charging/discharging, and no ESR offline reserves allowed.
  • Training outcomes to be seen in September/October with ERCOT publishing AS obligation reports.

Questions

  • Clarification on AS insufficiency process in RTC and its interaction with pricing.
  • Clarification on the role of SASM in relation to real-time co-optimization.
  • Potential for earlier testing of AS obligation reports for integration purposes.
  • Further illustration on the co-optimization of resource specific and AS only offers.

Next Steps

  • Address the implementation details of new AS only offers and their market impacts.
  • Further clarification on the functional differences between day-ahead and real-time operations for battery resources.
  • ERCOT to consider publishing AS obligation reports sooner for testing integration.
  • Continuing market training focusing on other key topics like battery operations in the day-ahead market.

▶️5.2 - Battery Training

5_RTCBTF_Battery-Overview-Training-4-22-25-as-of-4-17-25-1830.pdf

  • Overview of the progress and future integration of battery energy storage systems into the ERCOT system.
  • Increase in battery energy storage capacity from less than 200 megawatts in 2019 to over 11,000 megawatts today, with expectations of reaching 18,000 by the end of the year.
  • Duration of batteries in the system mainly consists of one-hour duration batteries, with a future trend towards longer duration batteries.
  • Implementation of real-time co-optimization where more ancillary services are expected to be provided by batteries.
  • Introduction to new NPRRs that support the transition such as NPRR1014, NPRR1204, NPRR1236 and the cleanup NPRR1246.
  • Details about the single model approach which includes registration, qualification, modeling, and telemetry as a single resource.
  • Modification of setpoint deviation calculation with tighter tolerance requirements being implemented.
  • Procedures for submission of energy bid offer curves and real-time management in the day-ahead and real-time markets.
  • RUC processes including DRUC and HRUC will be used to ensure enough capacity in future hours and how state of charge information will be utilized.
  • Deployment factors will simulate potential AS deployment used for future RUC calculations.
  • Discussion on how deployment factors are determined and how they can impact the market participants' operations.
  • Multiple questions were raised and answered about deployment factors, tolerances, and operating procedures.

▶️5.3 - RTC Spreadsheet Tool and Examples

RTC_RealTime_Market_Simulator_April-RTCBTF.pdf

  • Presentation used a simple model to illustrate price formation under RTC using different scenarios.
  • Ray Lee and the market analysis team were acknowledged for their contribution.
  • The presentation focuses on illustrating changes in outputs with RTC such as clearing prices, base points, and awards.
  • Simulation tool for scenarios is available on the RTC+B web page for download.
  • SCED system overview: designed to provide the lowest cost set of resources to meet energy needs, with reserve pricing added outside optimization.
  • RTC reflects scarcity of energy and ancillary services and factors ancillary service costs directly into LMPs.
  • Three scenarios presented: optimal allocation of ancillary services, transmission congestion management, and system scarcity impact.
  • Importance of making resources indifferent regarding capacity use for energy vs. ancillary services was emphasized.
  • Example scenarios demonstrated how RTC prioritizes the need to serve load and ensures operating profit consistency for resources.
  • RTC can alleviate congestion by adjusting ancillary service awards and managing costs effectively.
  • During tight conditions, RTC prioritizes energy over ancillary services and factors penalty costs.
  • Indifference in operating profit maintained irrespective of capacity use is essential.
  • Confirmation that offer cap remains at $5k in day-ahead but reduces to $2k for energy and ancillaries in real-time.

▶️6 - TWG Updates/Questions

6_RTCBTF_Reports_CDR_PD_04182025.pdf

▶️6.1 - Reports Update

  • Discussion on the timing and phases of report deliveries.
  • Reports will be delivered in multiple phases: no new reports on May 5, but introduction of wave one and wave two groups.
  • Group One involves open loop testing reports including RTC energy prices, binding constraints, adders, and market clearing prices for ancillary services.
  • Group Two involves closed loop testing, with seven additional reports and 11 new CDR reports available in September.
  • Some reports could be moved up to July for integration testing.
  • Reports are categorized as existing, modified, or new, with some changes not affecting the data itself.
  • The complete inventory includes around 95 reports, detailing when each will be released and any associated changes.
  • Dashboards and XSD files also discussed; XSDs available by October 15 for integration building.
  • The ERCOT reporting inventory tool, EMIL, was mentioned as a resource for tracking reports.
  • No significant changes in graphic/dashboard elements except for a few modifications.

▶️7 - Other Business

▶️7.1 - Next Steps on HEN Proposal related to underlying AORDC Calculations

7_HEN_Appropriate-Parameters-for-the-AORDC.pdf

  • Shams Siddiqi clarified that the HEN proposal does not seek to change the AORDC curve shape.
  • The proposal suggests using unaltered ORDC μ and σ for AORDC calculations.
  • Critique of the current process as cumbersome and based on regression fit that undervalues MCPC.
  • Advocated for using current ORDC hourly statistics for μ and σ.
  • Current AORDC uses μ* and  σ*, which are seen as incorrect proxies.
  • Shortcomings of the option two ORDC adder formula lead to undervaluing of reserves.
  • Using unaltered ORDC statistics could correct inadvertent price suppression.
  • No system changes required, just a manual update of parameters.
  • Could potentially address the missing money problem in current market pricing.
  • Some members are cautious about implementing significant changes before RTC go live.
  • Concerns over how these changes interact with future market design and reliability standards.
  • Need for broad analysis and simulations to understand full market impact.
  • Potential for an NPRR submission to facilitate further study.
  • Possible escalation to TAC and other bodies for higher-level discussion.
  • Some participants suggested considering this alongside broader market design changes post-RTC implementation.

▶️8 - Adjourn

Create a free trial account: Sign Up

Grid monitor is free to try. No credit card required


Already have an account? Login

Most Active PUCT Filings

APPLICATION OF ENTERGY TEXAS, INC. TO AMEND ITS CERTIFICATE OF CONVENIENCE AND NECESSITY FOR THE SETEX AREA RELIABILITY PROJECT IN JASPER, MONTGOMERY, NEWTON, POLK, SAN JACINTO, TRINITY, TYLER, AND WALKER COUNTIES - (305 filings)

CY 2024 ANNUAL POWER LINE INSPECTION & SAFETY REPORT IN PURSUANT TO 16 TAC § 25.97(F) - (83 filings)

APPLICATION OF CENTERPOINT ENERGY HOUSTON ELECTRIC, LLC FOR APPROVAL OF ITS 2026-2028 TRANSMISSION AND DISTRIBUTION SYSTEM RESILIENCY PLAN - (76 filings)

APPLICATION OF EL PASO ELECTRIC COMPANY FOR AUTHORITY TO CHANGE RATES - (73 filings)

PROJECT TO SUBMIT EMERGENCY OPERATIONS PLANS AND RELATED DOCUMENTS UNDER 16 TAC § 25.53 - (71 filings)

BROKER REGISTRATIONS - (61 filings)

COMPLAINT OF VALERO REFINING-TEXAS, LP AGAINST TEXAS-NEW MEXICO POWER COMPANY - (55 filings)